Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artif Organs ; 44(8): 856-872, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32187379

RESUMO

Cell-free and concentrated ascites reinfusion therapy (CART) is an effective therapy for refractory ascites. However, CART is difficult to perform as ascites filtration and concentration is a complicated procedure. Moreover, the procedure requires the constant assistance of a clinical engineer or/and the use of an expensive equipment for the multi-purpose blood processing. Therefore, we developed a CART specialized equipment (mobility CART [M-CART]) that could be used safely with various safety measures and automatic functions such as automatic washing of clogged filtration filter and self-regulation of the concentration ratio. Downsizing, lightning of the weight, and automatic processing in M-CART required the use of newly developed multi-ring-type roller pump units. This equipment was approved under Japanese regulations in 2018. In performing 41 sessions of CART (for malignant ascites, 22 sessions; and hepatic ascites, 19 sessions) using this equipment in 17 patients, no serious adverse event occurred. An average of 4494 g of ascites was collected and the total amount of ascites was processed in all the sessions without any trouble. The mean weight of the processed ascites was 560 g and the mean concentration ratio was 8.0. The ascites were processed at a flow rate of 50 mL/min. The mean ascites processing time was 112.5 minutes and a 106.5-minutes (95.2%) ascites processing was performed automatically. The operator responded to alarms or support information 3.2 times on average (3.1 minutes, 2.1% of ascites processing time). Human errors related to ascites processing were detected by M-CART at 0.4 times per session on average and were appropriately addressed by the operator. The frequencies of automatic washing of clogged filtration filter and self-regulation of the concentration ratio were 31.7% and 53.7%, respectively. The mean recovery rates (recovery dose) of protein, albumin, and immunoglobulin G were 72.9%, 72.9%, and 71.2% (65.9 g, 34.9 g, and 13.2 g), respectively. Steroids were administered in 92.7% of the sessions to prevent fever and the mean increase in body temperature was 0.53°C. M-CART is a compact and lightweight automatic CART specialized equipment that can safely and easily process a large quantity of ascites without the constant assistance of an operator.


Assuntos
Ascite/terapia , Filtração/instrumentação , Ascite/etiologia , Sistema Livre de Células , Filtração/métodos , Humanos , Neoplasias/complicações , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...